 SPDS wireless adaptor- User Manual  Page 2  1. Introduction   The following instructions  describe and  illustrate the  principle steps  involved in  installation of RFID  tags  operating  as  SPDS  bottom  valve  wireless  adaptor  and  SPDS  vapor  pressure  valve wireless adaptor.  The  SPDS  tag  is  portable,  reusable  electronic  device  designed  to  monitors  the  access  point through  sensors  and  generate  status  information  and  alarms  corresponding  to  various programmed conditions.  The wireless adaptor tag uses RFID (Radio Frequency Identification) wireless technology- and  includes a  transmitter/ receiver  unit, read/write  capability,  real-time clock, memory sensing circuitry for sealing verification.    2. Product Models This manual described the use of the products listed in the following table. Due to differences in regulations regarding the use of RF spectrum, a product should be used according to the following table:  Model Number Used in IG-SPV-40-433 Europe or where the EU directives apply. IG-SBV-40-433 IG-SBV-40-916 Where the FCC regulation apply. Forbidden for use in Europe. IG-SBV-40-916  3. Safety Precautions NOTE:  The  SPDS  wireless  adaptor  electronic  tag  is  powered  by  internal, irreplaceable  3.6V  cell;  do  not drill  into  or attempt  to  open any  part  of  the  tag housing.    USE HIGTEK APPROVED SERVICE Only approved service personnel must work on this product.  HAZARDOUS ENVIRONMENT The Use of wireless adaptor tag is subject to the product safety classification given in  section 6 : “ATEX product marking”, in this user guide. For all other safety aspects, Please refer to the enclosed EC- type examination certificate (page 8)   ACCESSORIES Use only approved accessories. Do not connect incompatible devices.  When connecting to any other device, please consult with Hi-G-Tek Engineering  Department prior to installation.
 SPDS wireless adaptor- User Manual  Page 3  The  device  must  not  be  used  within  non-conductive  flowing  media. To  the  externals  (Sensor-1,  Sensor-2,  Sensor-3  and  Common)  only  passive components, according to the user manual of the manufacturer, must be connected. Switches and resistors must meet the simple apparatus requirements according to EN 60079-11. Resistors must meet the current-limiting resistors requirements according to EN60079-11.  The  assembly  of the  connected  components  must  comply  with  the clearances and creepage distances requirements according to EN60079-11.  The FCC Wants You to Know  “This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1)   This device may not cause harmful interference and (2)   This  device  must  accept  any  interference  received,  including  interference  that  may cause undesired operation."  This equipment  has  been tested  and found to comply  with the limits  for  a Class B digital device,  pursuant  to  Part  15  of  the  FCC  rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the     receiver is connected. d) Consult the dealer or an experienced radio/TV technician. FCC Warning Modifications not expressly approved by the manufacturer could void the user authority to operate the equipment under FCC Rules. Instructions  concerning  human  exposure  to  radio  frequency  electromagnetic fields: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment.
 SPDS wireless adaptor- User Manual  Page 4   4. SPDS bottom valve wireless adaptor  Product Part No. IGSBV40xxx 4.1. General Adaptor shape is similar to the Data-Seal enclosure with the required modifications for cable connection. RF channels specifications are identical to the Data-Seal. 4.2. I/O’s The adaptor has 3 inputs and internal reed switch.  The internal reed switch is used to sense removing of the enclosure from installation fixture. A magnet should be installed in the fixture. See figure 1 and 2 for reed switch location. NCND D4X5mm magnet is recommended. Locate a magnet in one of reed switch ends. Each one of the three inputs can be configured to work in digital mode or analog mode. Digital mode gives the basic ON/OFF functionality without tamper proof of the cable. In analog mode, the sensor ON/OFF states are sensed and cable short or disconnect are sensed as well.                    4.3. Setting Digital /Analog mode   To work in digital mode simply connect the sensing switch to the cable. To work in analog mode connect the sensor according to Figure 3 below.         21.7736.5736.524.7Figure 3: Connecting the sensor: : 2Figure  Internal reed sw. location with rubber Jacket 1.6Meg 5%Sensing reed switch5.1Meg 5%: 1Figure  Internal reed sw. location without rubber Jacket SENSOR-3COMMONSENSOR-2SENSOR-1FRONT VIEW1234
 SPDS wireless adaptor- User Manual  Page 5   4.4. Input specifications:   Input type: Dry contact.  Polarity: Internally pulled HIGH, Activated when pulled LOW.  Protections: ESD.                                 4321FRONT VIEWPIN #4321BLACKREDGREENWHITEBLACKREDBLACKBLACKGREENWHITE SHIELDFigure 4: Extension cord (p/n IGSBVEC01): Pinout & wiring diagram:
 SPDS wireless adaptor- User Manual  Page 6    5. SPDS vapor pressure valve wireless adaptor   Product Part No. IGSPV40xxx  5.1. General Adaptor shape is similar to the DataSeal enclosure with the required modifications for cable connection. RF channels specifications are identical to the DataSeal. The adaptor controls the relay of the pneumatic system and reads the status of the air pressure.  5.2. I/O’s The adaptor has one input, one output and internal reed switch. The internal reed switch is used to sense removing of the enclosure from installation fixture. A magnet should be installed in the fixture. See figure 1 and 2 for reed switch location. NCND D4X5mm magnet is recommended. Locate a magnet in one of reed switch ends.  The input can be configured to work in digital mode or analog mode. Digital mode gives the basic ON/OFF functionality without tamper proof of the cable. In analog mode, the sensor ON/OFF states are sensed and cable short or disconnect are sensed as well. To work in digital mode simply connect the sensing switch to the cable.  To work in analog mode connect the sensor according to Figure 3.  5.3. Output specifications: The output is open drain type with specifications as follows:   Output type: Open-drain.  Maximum load: 24VDC relay with 230Ω minimum resistance.  Maximum open circuit voltage: 32V.  Functionality: ON- Pulse with configurable width.  Maximum ON pulse width: 10Sec.  Protection diode should be connected externally on relay terminals.    Extension cord (IGSPVEC01) pinout diagram:              PIN #4321REDGREENWHITEBLACK FRONT VIEW1234
 SPDS wireless adaptor- User Manual  Page 7   6. Technical specifications.  Power requirements Power Source 3.6V internal Lithium battery Life Expectancy 4 years at 50 readings per day Communication channels: Low frequency 125 kHz Low-frequency range Up to 40cm High frequency Model:IGSxV40433         433.92MHz  Model:IGSxV40916         916.50MHz High-frequency range Up to 100m (in open space) Antenna Characteristics Beam Divergence      Omni-directional on non-metal wall        Hemispherical on metal wall Polarization Vertical Physical Characteristics: Dimensions 63 x 49 x 37mm (without pin and lock) Weight 150gr Environmental Conditions  Operating Temperature : -40°C to +70°C  Storage Temperature  : -40°C to +80°C  Protection Classification : IP65 I/Os Input type   Dry contact      Polarity Internally pulled HIGH, Activated when pulled LOW. Protections: ESD.
 SPDS wireless adaptor- User Manual  Page 8  7. ATEX Marking        II – Equipment Group II:  Surface (no-mining) equipment.  2 - Equipment Category 1: Very high degree of protection for use in Zone 0.   G – Atmosphere Group: Gases, Vapors, Mists  Ex-   Explosion proof equipment:  The Equipment that has been certified for use in a Potentially Explosive Atmosphere  ia - A protection technique based upon the restriction of electrical energy within the apparatus and in the interconnecting wiring, exposed to a explosive atmosphere, to a level below that which can cause ignition by either sparking or heating effects. “ia” -  Indicates that the  electric circuit is not able to cause an ignition when there are two failures (“ib” is for a single failure situation).  IIB - Gas group B: Ethylene - typical gas in petrochemical environment.   T4- Temperature classification (max.135ºC)                     Ex ia IIB T4 05399 II 1 G